It is known that treatment of periodontitis begins with the mechanical removal of deposits on the tooth surface and remove biplenok, and for this also applied ultrasonic devices. The aim of the present study was to evaluate the clinical efficacy of ultrasound device vector, which differs from previously known devices and techniques of manual scaling and watering the roots that generate a special type of oscillation. EOG Resources will undoubtedly add to your understanding. As shown studies in patients in whom treatment of periodontitis was the unit vector, pocket probing depth was significantly less. Also, after dental treatment unit vector could be observed significant increase in attachment of the gums. Chronic periodontitis causes destructive changes in periodontal tissues, including the supporting apparatus of teeth and can lead to tooth extraction and as a consequence, the need for prosthetics. Treatment is aimed at to resolve inflammation and possibly contribute to regeneration of lost periodontal tissues.
To achieve these goals apply to both surgical and conservative treatments periodontitis. When conservative treatment is applied over and subgingival scaling and polishing the root. To this end, the disposal of the dentist is the traditional hand tools, as well as furcation than manual achieve a smooth surface operational polyNet need sharpening instrumentK disadvantages include the formation of aerosols in the work and the need for continuous suction of fluid, reduced tactile control and surface roughness on a microscopic level. The instrument vector is different from other types of devices used oscillation. Fluctuations that occur at the tip to deviate by 90 "due to the horizontal deformation of the metal ring in its compressed, resulting in the appearance of the longitudinal vibrations along the axis of the instrument. Also, the longitudinal vibrations do not cause heating of the nozzle and allow to dispense with the coolant, then you can opt out of intensive continuous suctioning of potentially contaminated with bacteria aerosols, as when working with ordinary devices. The advantage of the fact that treatment is more gentle and minimally traumatic to tissue, and virtually painless.
Treatment of periodontitis unit vectors leads to increased level of attachment of the gums. Also, various studies have shown that in the furcations of sonic and ultrasonic instruments more efficient than hand tools. Conservative treatment of periodontitis with Using the new device vector showed more effective results reducing probing depth and increased clinical attachment of the gums as compared with the technique of hand scaling and curette polish roots. The difference in the level of attachment of the gums much.